ดีไซน์ที่ไม่มีชื่อ

Double-head Industrial Anti Static High Frequency Ionizing Air Blower
KF-40AR

179
1694659268091
1694659317651
01 Front window
The front window can be flexibly disassembled then automatically power off. Built-in automatic cleaning discharge needle structure maintenance-free. The brush made of special materials make cleaning more thorough.
Accessory can be purchased separately
02 Discharge needle
Discharge needle parts can be disassem-bled for replacement and maintenance. Tungsten alloy discharge needle with 99.99% tungsten content. Each needle produces both positive and negative ions enabling an electronic balbnce system.
Accessory can be purchased separately.
03 Rear window
Metal window mesh (120x120 standard accessory for fan)
Filter window
Accessory can be puchased separately.
04 Housing
Powder coating process with standard white powder.
05 Mounting bracket
06 Operation panel and function setting buttins.
07 Power supply
Input power supply AC220V/50Hz or AC 110V/60Hz

Product Features
1. When Cleaning the fan is reversed to prevent foreign objects from blowing towards the product.
2. The automatic ion balabce system can achieve ion balance within 0±10V.
3. Different lengths of ion fans can be selected based on the workbench and product size.
4. Equipped with automatic cleaning discharge discharge needle function, it can reduce the frequency of daily manual
5. Equipped with complete machine locking function, wireless monitoring function and supports two modes : LORA+NB loT.
6. According to the workshop environment, the cleaning and discharge needle time can be adjusted from 0 to 999 hours through LED digital display.

Technical Parameters

Product ModelKF-40AR
Input power supply voltageDC24V
Decay normal operation indicator lightif decay operation is normal the green indicator light is on
Decay abmormal indicator lightif decay operation is abnormal the red indicator light is on
Decay timeabout 1.0s (300mm)
Ion balanceAutomatic ion balance system 0±10V
Air volume2.44-5.1m3/min (constant air flow)
Ozone concentrationBelow 0.03ppm (distance 150mm)
Applied environmental temperature0~40℃(no condensation)
Applied environmental humidity30-70% RH (no water drop condensation)
Overall size/mm400*82*150 (exclouding stents)