Ion air nozzle is a kind of small device which is used for static elimination professional.It use the compressed air to blow out of the air flow, at the same time, it will produce a large number of positive and negative charges which is depend on the electrode needle,It can neutralize surface of charge and eliminate static electricity.It not only small but also easy to install,stable performance.Airflow velocity may be regulated and fast to eliminate static electricity.
Product Features
1. Automatic ion balance system, ion balance can reach 0±10V or less.
2. Built-in high-pressure system, small size, safe and convenient.
3. Equipped with scenic spots running lights and high pressure abnormal alarm indicator.
4. According to the use of different places, choose different nozzle.
5. With tungsten alloy discharge needle, hard to wear if long-term using.
6. Shell wall sprayed metal paint, so that the entire body ground shield.
Technical Parameters
| Product Model | KZ-10C |
| Output voltage | AC2200V |
| Current consumption | 500mA |
| Pressure | 0.05-0.5MPa |
| Operation Temperature | 0-40℃ |
| Operation Humidity | 30-70%RH |
| Ozone concentration | <0.03ppm(200mm distance) |
| Piping connection caliber | Φ6 |
| Size | 104.5*56.5*22mm |
| Weight | 0.09kg |
| Filtration accuracy | 0.1μm |
| Filtration efficiency | 0.999 |
| Ion Balance | ±10V |

01 Indicators
POWER/Power indicator (Green)
H.V/High voltage normal operation (Green)
H.V ALARM/High voltage abnormal operation (Red)
Alarm when HV system abnormal
02 High voltage box
Inside the ceramic HV generator and tungsten alloy discharge needle.
03 Nozzle
Variety of nozzle heads can be choose according to the anti static requirements and the applied situation.
(Performance parameters refer to P14 high frequency nozzle specification.)
04 Caramic protection tube
05 Nozzle holder
06 Filter (optional)
(Performance parameters refer to P18 filter apecification.)
07 Regulation valve
08 Power socket
09 Power cable
10 2-M3 (mounting hole)